Topcon GPT-2003 Manuel d'utilisateur Page 109

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 168
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 108
9 MEMORY MANAGER MODE
9-4
To edit the data in searching mode
Point name (PT#, BS#) , ID, PCODE and Height data (INS.HT, R.HT) can be corrected in the searching
mode.
Measured value can not be corrected.
Operating procedure Operation Display
1 Press the [F1](EDIT) key from last page of
displayed data.
[F1]
2 Select the item to correct by pressing [ ]or[ ]
key.
[ ]or[ ]
3 Press the [F1](INPUT) key and enter data. *1)
Press the [F4](ENT) key.
4 Press the [F4](ENTER) key.
[F1]
Enter Data
[F4]
[F4]
5 Press the [F3](YES) key .
[F3]
*1) Refer to Section 2.6 “How to Enter Alphanumeric characters”.
When editing, ID and PCODE are not linked with PCODE LIBRARY.
Even though the height data (INS.HT, R.HT) are corrected, the measured value can not be corrected.
PT#
TOP-104 2/2
PCODE
R.HT
1.000 m
EDIT
PT#
TOP-104
PCODE :
R.HT : 1.000 m
INPUT ––– ––– ENTER
PT# :TOP-104
PCODE :
R.HT
1.000 m
INPUT ––– ––– ENTER
PT#
TOP-104
PCODE :
R.HT : 1.200 m
>SAVE? [YES][NO]
PT#
TOP-104 2/2
PCODE
R.HT
1.200 m
EDIT
Vue de la page 108
1 2 ... 104 105 106 107 108 109 110 111 112 113 114 ... 167 168

Commentaires sur ces manuels

Pas de commentaire