22 ERROR DISPLAYS
22-2
If error still persist after attempting to clear them, contact your local Topcon dealer or Topcon head
ofce.
CIRCULAR
ERROR
Known points and occupied point are on the
same circle at the resection mode.
Take the different point.
PT# EXIST
Same new point name is already memorized
in the memory.
Conrm the new point name and input
again.
PT# DOES
NOT EXIST
When you enter incorrect name or PT# does
not exist in the internal memory.
Enter the correct name or enter point in the
internal memory.
RANGE
ERROR
When setting a new point, calculation is
impossible from the measured data.
Measure again.
Tilt Over
Instrument tilts over more than
3 minutes.
Level the instrument properly.
V ANGLE
ERROR
H ANGLE
ERROR
VH ANGLE
ERROR
Abnormality in angle measuring system.
If this error code continues to display, repair is
required.