Topcon GPT-2003 Manuel d'utilisateur Page 115

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 168
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 114
9 MEMORY MANAGER MODE
9-10
9.4 Coordinate Data Direct Key Input
Coordinate data for the layout point or control point can be input directly from the keyboard. This data
can be stored into a le in the internal memory.
Operating procedure Operation Display
1 Press the [F3](MEMORY MGR.) key from the
menu 1/3.
[F3]
2 Press the [F4](P
) key.
[F4]
3 Press the [F1](COORD. INPUT) key.
[F1]
4 Press the [F1](INPUT) key and enter File Name
you want to input.
Press the [F4](ENT) key. *1)
[F1]
Enter FN
[F4]
5 Press the [F1](INPUT) key and enter PT#.
Press the [F4](ENT) key. *1)
[F1]
Enter PT#
[F4]
6 Enter coordinate data in the same way.
Next input display is shown, point number (PT#) is
automatically incremented.
[F1]
Enter COORD.
[F4]
*1) Refer to Section 2.6 “How to Enter Alphanumeric characters”.
MEMORY MGR. 1/3
F1:FILE STATUS
F2:SEARCH
F3:FILE MAINTAN P
MEMORY MGR. 2/3
F1:COORD. INPUT
F2:DELETE COORD.
F3:PCODE INPUT P
SELECT A FILE
FN:_________
INPUT LIST ––– ENTER
COORD. DATA INPUT
PT#:_________
INPUT ––– ––– ENTER
N
100.234 m
E: 12.345 m
Z: 1.678 m
INPUT ––– ––– ENTER
COORD. DATA INPUT
PT#:TOPCON-102
INPUT ––– ––– ENTER
Vue de la page 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 167 168

Commentaires sur ces manuels

Pas de commentaire