Vue de la page 16
1-6
1 NOMENCLATURE AND FUNCTIONS
Page Display
Soft
key
Function
Slope
distance
measuring
MEAS F1
Starts slope distance measurement mode.
Changes Continuous/ N-times (single) measurement mode.
MODE F2 Changes Fine / Coarse(1mm) /Coarse(10mm) mode.
VH F3 Angle measurement mode.
HD F4
Horizontal distance measurement mode. Displays the horizontal distance
data after N-times or single measurement.
NEZ F5
Coordinate measurement mode.
Displays the coordinate after N-times or single measurement.
TURN F1 Turns the instrument to required angle automatically.
SO F2 Stake out measurement mode.
MEAN F3 Sets the number of N-time measurement.
m/ft F4 Changes distance measurement unit to meter or feet.
Horizontal
distance
measuring
MEAS F1
Starts horizontal distance measurement mode.
Changes continuous/ N-times (single) measurement mode.
MODE F2 Changes Fine / Coarse(1mm) /Coarse(10mm) mode.
VH F3 Angle measurement mode.
SD F4
Slope distance measuring mode.
Display the slope distance after N-times or single measurement.
NEZ F5
Coordinate measurement mode.
Displays the coordinate after N-times or single measurement.
TURN F1 Turns the instrument to required angle automatically.
SO F2 Stake out measurement mode.
MEAN F3 Sets the number of N-time measurement.
m/ft F4 Switches meter or feet unit.
Coordinate
measuring
MEAS F1
Starts coordinate measurement mode.
Changes continuous/ N-times (single) measurement mode.
MODE F2 Changes Fine / Coarse(1mm) /Coarse(10mm) mode.
VH F3 Angle measurement mode.
SD F4
Slope distance measuring mode.
Display the slope distance after N-times or single measurement.
HD F5
Horizontal distance measurement mode. Displays the horizontal distance
data after N-times or single measurement.
TURN F1 Turns the instrument to required angle automatically.
HT F2 Input Instrument / prism height values.
MEAN F3 Sets the number of N-time measurement.
m/ft F4 Switches meter or feet unit.
SET F5 Pre-set instrument coordinate values.
Vue de la page 16