Topcon GPT-2003 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Mesure, test et contrôle Topcon GPT-2003. Topcon GPT-2003 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 168
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - GPT-2000

GPT-2000 SERIESGPT-2003GPT-2005GPT-2006GPT-2009PULSE TOTAL STATION INSTRUCTION MANUAL

Page 2

8 9.7.2 Loading Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-149.7.3 Setting Parame

Page 3 - FOREWORD

8 LAYOUT8-118.3 Setting a New PointNew point is required for example when a layout point cannot be sighted from existing control points.8.3.1 Side

Page 4

8 LAYOUT8-126Press the [F4](ENTER) key.The file will be set .[F4]7 Press the [F1](INPUT) key, and enter the new point name. *4)Press the [F4](ENT) k

Page 5

8 LAYOUT8-138.3.2 Resection MethodSet up the instrument at a new point, and calculate the coordinate of the new point using the coordinate data of

Page 6

8 LAYOUT8-145Enter instrument height in the same way.[F1]Enter INS.HT[F4]6 Enter the known point A number. *3)[F1]Enter PT#[F4]7 Enter reflector hei

Page 7 - FROM THIS APERTURE

8 LAYOUT8-1513 Press the [F4](CALC) key. *6)Standard Deviation will be shown.Unit : (sec.) or (mGON) or (mMIL)[F4]14 Press the [F2](↓) key.Standar

Page 8 - Contents

8 LAYOUT8-16● Viewing PT# LISTYou can see the PT# List and enter the data from the List, also you can see coordinate data of a point.[Example: Ex

Page 9

9 MEMORY MANAGER MODE9-19 MEMORY MANAGER MODEThe following items for internal memory are available in this mode.1) FILE STATUS : Checking the numbe

Page 10

9 MEMORY MANAGER MODE9-29.1 Display Internal Memory StatusThis mode is used to check the internal memory status. Operating procedure Operation Disp

Page 11 - Standard Set Composition

9 MEMORY MANAGER MODE9-39.2 Searching Data This mode is used to search the recorded file data in the DATA COLLECT or LAYOUT mode.The following 3 sea

Page 12 - 1 NOMENCLATURE AND FUNCTIONS

9 MEMORY MANAGER MODE9-4● To edit the data in searching modePoint name (PT#, BS#) , ID, PCODE and Height data (INS.HT, R.HT) can be corrected in t

Page 13

9 Standard Set Composition 1) GPT-2000 series (with lens cap) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 each2) On-board Battery B

Page 14 - 1.2 Display

9 MEMORY MANAGER MODE9-59.2.2 Coordinate Data SearchingExample searching :Point number searching Operating procedure Operation Display1 Press the [

Page 15 - Keys Name of Key Function

9 MEMORY MANAGER MODE9-69.2.3 PCODE LIBRARY SearchingExample searching :Number searching Operating procedure Operation Display1 Press the [F3](MEMO

Page 16 - Coordinate measurement mode

9 MEMORY MANAGER MODE9-79.3 FILE MAINTENANCE In this mode, the following items are available.Renaming file name / Searching data in a file / Deletin

Page 17 - N, E, Z, HR (or V,H,SD,N,E,Z)

9 MEMORY MANAGER MODE9-89.3.1 Rename a FileAn existing file in internal memory can be renamed. 9.3.2 Searching Data in a FileAn existing file in inte

Page 18 - 2 PREPARATION FOR MEASUREMENT

9 MEMORY MANAGER MODE9-99.3.3 Deleting a FileThis mode erases a file from internal memory. Only one file can be erased at a time.Operating procedure

Page 19

9 MEMORY MANAGER MODE9-109.4 Coordinate Data Direct Key Input Coordinate data for the layout point or control point can be input directly from the

Page 20 - 2.3 Power Switch Key ON

9 MEMORY MANAGER MODE9-119.5 Delete a Coordinate Data from a FileCoordinate data in a file can be erased.Operating procedure Operation Display1 Pres

Page 21 - 0SET HOLD HSET P1

9 MEMORY MANAGER MODE9-129.6 Editing PCODE LibraryPCODE data can be entered into PCODE Library in this mode.A PCODE is linked with a number of 1 to

Page 22

9 MEMORY MANAGER MODE9-139.7 Data CommunicationsYou can send a data file stored in the internal memory to a computer directly. Also, you can directl

Page 23

9 MEMORY MANAGER MODE9-149.7.2 Loading DataCoordinate data files and PCODE Library data can be loaded from PC. Example: Loading a coordinate data fil

Page 24

1-1 1 NOMENCLATURE AND FUNCTIONS 1 NOMENCLATURE AND FUNCTIONS 1.1 NomenclaturePoint guide(Point guide type only)Objective lensDisplay unitHan

Page 25 - Turning the Point Guide OFF:

9 MEMORY MANAGER MODE9-159.7.3 Setting Parameter of Data Communications● Items of the Parameter● Example Setting Baud rate : 4800Item Selecting

Page 26 - Symbol mark

9 MEMORY MANAGER MODE9-169.8 InitializationThis mode is used to initialize the internal memory.Following data can be initialized.FILE DATA :All file

Page 27 - 3 ANGLE MEASUREMENT

10 SET AUDIO MODE10-110 SET AUDIO MODEThe light acceptance quantity level for the EDM (SIGNAL), the atmospheric correction value (PPM), correction

Page 28 - Display angle

11 SETTING THE PRISM / NON-PRISM CONSTANT VALUE11-111 SETTING THE PRISM / NON-PRISM CONSTANT VALUEThe prism constant value of Topcon is set to zer

Page 29

12 SETTING ATMOSPHERIC CORRECTION12-112 SETTING ATMOSPHERIC CORRECTIONThe velocity of light through air is not constant and depends on the atmosph

Page 30

12 SETTING ATMOSPHERIC CORRECTION 12-2 ● How to Set the Atmospheric Correction Value Directly Measure the temperature and air pressure to find atmo

Page 31

12 SETTING ATMOSPHERIC CORRECTION 12-3 Atmospheric Correction Chart (For your reference) The atmospheric correction value is obtained easily with

Page 32

12 SETTING ATMOSPHERIC CORRECTION 12-4

Page 33 - 4 DISTANCE MEASUREMENT

12 SETTING ATMOSPHERIC CORRECTION 12-5

Page 34

13 CORRECTION FOR REFRACTION AND EARTH CURVATURE 13-1 13 CORRECTION FOR REFRACTION AND EARTH CURVATURE The instrument measures distance, taking in

Page 35 - 4.4 Distance Measurement

1-2 1 NOMENCLATURE AND FUNCTIONS*The position of vertical motion clamp and Vertical tangent screw will differ depending on the market.Sighting

Page 36

14 POWER SOURCE AND CHARGING14-114 POWER SOURCE AND CHARGING14.1 On-board Battery BT-52QA● To remove1 Push the battery locking lever and pull out t

Page 37 - 4.6 Stake Out (S.O)

14 POWER SOURCE AND CHARGING14-2● To installPlace the base of the on-board battery into the GPT-2000 series, push the on-board battery toward the i

Page 38 - 4.7 Offset Measurement

15 DETACH/ATTACH OF TRIBRACH15-115 DETACH/ATTACH OF TRIBRACHThe instrument is easily detached or attached to the tribrach, with a tribrach locking

Page 39

16 SELECTING MODE16-116 SELECTING MODE16.1 Items of the Selecting ModeThe following modes are available.Menu Items Selecting item Display1:UNIT SET

Page 40

16 SELECTING MODE16-2EDM OFF TIME0-99 The time when EDM is cut off from distance measurement is completed can be changed. This function is effecti

Page 41

16 SELECTING MODE16-3*LANGUAGE selection is different in different countries.16.2 How to Set Selecting Mode<Example> : Setting unit in hPa,

Page 42

16 SELECTING MODE16-47 Press [F3](OTHERS SET) key.[F3]8 Press [F4](P↓) key, to get the function in page 2 .[F4]9 Press [F1] key.[F1]10 Press [F1](O

Page 43

17 CHECK AND ADJUSTMENT17-117 CHECK AND ADJUSTMENT17.1 Checking and adjusting of instrument constantNormally, the instrument constant does not hav

Page 44

17 CHECK AND ADJUSTMENT17-217.2 Checking the Optical AxisTo check if the optical axis of EDM and theodolite are matched, follow the procedure below

Page 45

17 CHECK AND ADJUSTMENT17-310) Move the collimating point to the center of prism gradually until buzzer sound starts.Tur ning the horizontal tange

Page 46

1-3 1 NOMENCLATURE AND FUNCTIONS 1.2 Display ● Display The display uses a dot matrix LCD which has 4 lines and 20 characters per line. In gen

Page 47 - 5 COORDINATE MEASUREMENT

17 CHECK AND ADJUSTMENT17-417.3 Checking/Adjusting the Theodolite Functions● Pointers on the Adjustment1) Adjust the eyepiece of the telescope prop

Page 48 - Enter R. HT

17 CHECK AND ADJUSTMENT17-517.3.1Checking /Adjusting the Plate LevelAdjustment is required if the axis of the plate level is not perpendicular to t

Page 49 - Set direction

17 CHECK AND ADJUSTMENT17-617.3.3Adjustment of the Vertical Cross-hairAdjustment is required if the vertical cross-hair is not in a place perpendic

Page 50 - 6 SPECIAL MODE (Menu Mode)

17 CHECK AND ADJUSTMENT17-717.3.4Collimation of the InstrumentCollimation is required to make the line of sight of the telescope perpendicular to t

Page 51

17 CHECK AND ADJUSTMENT17-817.3.5Checking / Adjusting the Optical Plummet TelescopeAdjustment is required to make the line of sight of the optical

Page 52

17 CHECK AND ADJUSTMENT17-917.3.6Checking / Adjusting the Laser Plummet (For Laser Plummet type)● Check1) Turn on the laser plummet and coincide th

Page 53

17 CHECK AND ADJUSTMENT17-1017.3.7Adjustment of Vertical Angle 0 DatumIf when measuring the vertical angle of target A at telescope position norma

Page 54

17 CHECK AND ADJUSTMENT17-1117.4 How to Set the Instrument Constant ValueTo set the Instrument constant which is obtained in Section 17.1 “Check a

Page 55 - Collimate

17 CHECK AND ADJUSTMENT17-1217.5 Adjustment of Compensation Systematic Error of Instrument(Only for GPT-2003/2005/2006)Operating procedure Operatio

Page 56

17 CHECK AND ADJUSTMENT17-1314Press the [F4](SET) key. Repeat the procedures in step 13 and 14 so that the count of measured times matches to the o

Page 57

1-4 1 NOMENCLATURE AND FUNCTIONS1.3 Operating Key1.4 Function Key (Soft Key)The Soft Key message is displayed at the bottom line of display. The f

Page 58

18 PRECAUTIONS18-118 PRECAUTIONS1) For transportation, hold by the handle or yoke of the instrument. Never hold by the lens barrel as it can affect

Page 59

19 SPECIAL ACCESSORIES19-119 SPECIAL ACCESSORIESData entry keyboard DK-7Occupied point, coordinate data and other data can be input from DK-7. It i

Page 60

19 SPECIAL ACCESSORIES19-2Mini prism The mini prism (25.4mm) is made from precision ground glass and mounted in high impact plastic housings.● The

Page 61

19 SPECIAL ACCESSORIES19-3Aluminum extension leg tripod, Type E● Flat head 5/8" × 11 threads with adjustable legs.Wide-frame extension leg tri

Page 62

20 BATTERY SYSTEM20-120 BATTERY SYSTEMIn case of On-board battery In case of External battery PackBT-3QBT-3L AC-5Car batteryBT-52QAGPT-2000 seriesG

Page 63

21 PRISM SYSTEM21-121 PRISM SYSTEMArrangement according to your needs is possible.It is possible to change the combination according purpose.Use th

Page 64

22 ERROR DISPLAYS22-122 ERROR DISPLAYSError codeDescription Countermeasures3 points requiredWhen area calculating, there are lessthan 3 points coor

Page 65 - 6.2 Setting the GRID FACTOR

22 ERROR DISPLAYS22-2● If error still persist after attempting to clear them, contact your local Topcon dealer or Topcon head office.CIRCULARERRORKn

Page 66

23 SPECIFICATIONS23-123 SPECIFICATIONSTelescopeLength : 150mmObjective lens : 45mm (EDM 50mm)Magnification : 30×Image : ErectField of view : 1°30&ap

Page 67 - 6.4 Setting Mode 1

23 SPECIFICATIONS23-2Least Count in Measurement Fine measurement mode : 1mm (0.005ft.) / 0.2mm (0.001ft.) Coarse measurement mode : 10mm (0.02ft.

Page 68

1-5 1 NOMENCLATURE AND FUNCTIONSAngle measurementDistance measurement modeCoordinate measurement modePageSoftkeyDisplaymarkFunction1F1 0SET Ang

Page 69

23 SPECIFICATIONS23-3Laser Plummet (only for Laser plummet type)Light source : L.D (Visible laser)Wave length : 633nmOut put : 1mW maximumLaser cla

Page 70

APPENDIXAPPENDIX-1APPENDIX3 Dual Axis CompensationInclination of the vertical axis with respect to true vertical will result in incorrectly measure

Page 71 - 7DATA COLLECTION

APPENDIXAPPENDIX-2It is clear from the table that dual axis compensation has the most benefit when the elevation of the target i

Page 72

APPENDIXAPPENDIX-34 Precaution when Charging or Storing BatteriesThe capacity of battery will be affected and its service life shortened in any of

Page 73 - 7.1 Preparation

APPENDIXAPPENDIX-40102030 405060204060801001200Ambient temperature when charging(℃) Charging efficiency (discharge capacity(%))0.1C chargeFig.1 Rec

Page 74

APPENDIXAPPENDIX-5

Page 77

TOPCON CORPORATION75-1 Hasunuma-cho,Itabashi-ku,Tokyo,174-8580 Japan Phone:3-3558-2520 Fax:3-3960-4214 http:// www.topcon.co.jpPULSE TOTAL STATION

Page 78

1-6 1 NOMENCLATURE AND FUNCTIONS1.5 Serial signal RS-232C connectorThe serial signal connector is used for connecting the GPT-2000 series with a c

Page 79

2-1 2 PREPARATION FOR MEASUREMENT2 PREPARATION FOR MEASUREMENT2.1 Power Connection (unnecessary if on-board Ni-MH battery BT-52QA is used)See below

Page 80 - ● Column offset measurement

2-2 2 PREPARATION FOR MEASUREMENT2.2 Setting Instrument Up For MeasurementMount the instrument to the tripod. Level and center the instrument precis

Page 82

2-3 2 PREPARATION FOR MEASUREMENT2.3 Power Switch Key ON1 Confirm the instrument is leveled.2 Press the power key..● Confirm the battery power remaini

Page 83

2-4 2 PREPARATION FOR MEASUREMENT2.4 Battery Power Remaining DisplayBattery power remaining display indicates the power condition.Note: 1 The batte

Page 84

2-5 2 PREPARATION FOR MEASUREMENT2.5 Vertical and Horizontal Angle Tilt Correction(GPT-2009 has vertical angle tilt correction only.)When the tilt s

Page 85

2-6 2 PREPARATION FOR MEASUREMENT● Setting Tilt Correction by Soft KeyTo enable you to select tilt ON/OFF function. setting is not memorized after

Page 86

2-7 2 PREPARATION FOR MEASUREMENT2.6 How to Enter Alphanumeric charactersThis enables you to enter alphanumeric characters such as the instrument he

Page 87 - 7.4 NEZ Auto Calculation

2-8 2 PREPARATION FOR MEASUREMENT● To correct a character, move the cursor to correct character by pressing [ ] or [ ] key and enter again.2.7 Poin

Page 88

2-9 2 PREPARATION FOR MEASUREMENT2.8 Laser Plummet ON/OFF (Only for Laser Plummet type)Laser plummet option will help you to center the instrument e

Page 89 - Menu Selecting Item Contents

3-1 3 ANGLE MEASUREMENT3 ANGLE MEASUREMENT3.1 Measuring Horizontal Angle Right and Vertical Angle Make sure the mode is in Angle measurement.Operati

Page 90 - 8LAYOUT

3-2 3 ANGLE MEASUREMENT 3.2 Switching Horizontal Angle Right/Left Make sure the mode is Angle measurement. 3.3 Measuring from the Required Horizo

Page 91

3-3 3 ANGLE MEASUREMENT 3.3.2 Setting a Horizontal Angle from the Keys Make sure the mode is Angle measurement . 3.4 Vertical Angle Percent Grade

Page 92 - Grid Factor

1 FOREWORD Thank you for purchasing the TOPCON Pulse Total Station, GPT-2000 series. For the best performance of the instruments, please carefully re

Page 93

3-4 3 ANGLE MEASUREMENT 3.5 Repetition Angle Measurement ● Repetition angle measurement can be done by horizontal angle right measurement mode.Ma

Page 94

3-5 3 ANGLE MEASUREMENT3.6 Buzzer Sounding for Horizontal Angle 90° IncrementsWhen the horizontal angle falls in the range of less than ± 1° of 0°,

Page 95 - Enter coord

3-6 3 ANGLE MEASUREMENT3.7 Compasses ( vertical angle)Vertical angle is displayed as shown below.Operating procedure Operation Display1 Press the [F

Page 96

4-1 4 DISTANCE MEASUREMENT4 DISTANCE MEASUREMENT● Prism mode and Non-prism modeIn GPT-2000 series, the distance measurement will be done using invis

Page 97

4-2 4 DISTANCE MEASUREMENT4.3 Distance Measurement (Continuous Measurement)Make sure the mode displays angle measurement.Operating procedure Operati

Page 98 - 8.2 Executing a Layout

4-3 4 DISTANCE MEASUREMENT4.4 Distance Measurement (N-time Measurement/Single Measurement)When the number of times measurement is preset, the GPT-20

Page 99

4-4 4 DISTANCE MEASUREMENT● Choose meter /feet / feet+inch unit by soft keyIt is possible to change the unit for distance measurement mode by soft k

Page 100 - 8.3 Setting a New Point

4-5 4 DISTANCE MEASUREMENT4.6 Stake Out (S.O)The difference between the measured distance and the input stake out distance is displayed.Measured dis

Page 101

4-6 4 DISTANCE MEASUREMENT4.7 Offset MeasurementThere are four offset measurement modes in the Offset Measurement.● Angle offset● Distance offset● P

Page 102

4-7 4 DISTANCE MEASUREMENT4.7.1 Angle OffsetThis mode is useful when it is difficult to set up the prism directly, for example at the center of a tre

Page 103

2 General Handling PrecautionsBefore starting work or operation, be sure to check that the instrument is functioning correctly with normal performa

Page 104

4-8 4 DISTANCE MEASUREMENTThe horizontal distance from the instrument to the prism will be measured.5 Collimate point A0 using the horizontal motion

Page 105

4-9 4 DISTANCE MEASUREMENT4.7.2 Distance Offset MeasurementMeasuring distance and coordinate of the center of a pond or a tree of which the radius i

Page 106 - 9 MEMORY MANAGER MODE

4-10 4 DISTANCE MEASUREMENTAfter measuring, the result added offset value will be shown. 6 Show the relative elevation of point P0.● Each time pres

Page 107

4-11 4 DISTANCE MEASUREMENT4.7.3 Plane Offset MeasurementMeasuring will be taken for the place where direct measuring can not be done, for example d

Page 108 - 9.2 Searching Data

4-12 4 DISTANCE MEASUREMENT6 Measure the second and third points in the same way.Collimate P2[F1]Collimate P3[F1]The instrument calculates and displ

Page 109

4-13 4 DISTANCE MEASUREMENT4.7.4 Column Offset MeasurementIf it is possible to measure circumscription point (P1) of column directly, the distance t

Page 110

4-14 4 DISTANCE MEASUREMENT6 Collimate the center of the column (P1) and press the [F1](MEAS) key.N-time measuring will start.After the measurement,

Page 111

5-1 5 COORDINATE MEASUREMENT5 COORDINATE MEASUREMENT5.1 Setting Coordinate Values of Occupied Point Set the coordinates of the instrument (occupied

Page 112 - 9.3 FILE MAINTENANCE

5-2 5 COORDINATE MEASUREMENT5.2 Setting Height of the InstrumentIt is possible to retain the height of instrument after turning the power off. Refer

Page 113

5-3 5 COORDINATE MEASUREMENT5.4 Execution of Coordinate MeasuringMeasure the coordinates by entering the instrument height and prism height, coordin

Page 114

3 Display for Safe Use In order to encourage the safe use of products and prevent any danger to the operator and others or dama

Page 115 - Enter COORD

6 SPECIAL MODE (Menu Mode)6-16 SPECIAL MODE (Menu Mode)By pressing the [MENU] key, the instrument will be in MENU mode.In this mode, special measur

Page 116

6 SPECIAL MODE (Menu Mode)6-26.1 Application Measurement (PROGRAMS)6.1.1 Remote Elevation measurement (REM)To obtain elevation of the point at whi

Page 117 - 9.6 Editing PCODE Library

6 SPECIAL MODE (Menu Mode)6-32) Without prism height inputHorizontal distance (HD) between the instrument and prism will be shown.8 Collimate targe

Page 118 - 9.7 Data Communications

6 SPECIAL MODE (Menu Mode)6-4The prism position will be decided. 7 Collimate ground point G.Collimate G8 Press the [F4](SET) key.The position of po

Page 119

6 SPECIAL MODE (Menu Mode)6-56.1.2 Missing Line Measurement (MLM) Measurement for horizontal distance (dHD), slope distance (dSD), elevation (dVD)

Page 120 - Item Selecting Item Contents

6 SPECIAL MODE (Menu Mode)6-65 Press the [F1] or [F2] key to select usingGRID FACTOR.[Example:F2 : DON’T USE][F2]6 Press the [F1] key.[F1]7 Collima

Page 121 - 9.8 Initialization

6 SPECIAL MODE (Menu Mode)6-7● How to use coordinate dataIt is possible to input coordinate value directly or calculate from coordinate data fileThe

Page 122 - 10 SET AUDIO MODE

6 SPECIAL MODE (Menu Mode)6-86.1.3 Setting Z Coordinate of Occupied PointOccupied point coordinate data and known point actual measuring data are u

Page 123

6 SPECIAL MODE (Menu Mode)6-92) Z Coordinate Calculation from Known Point Measuring Data[Example setting] Using coordinate data fileOperating proced

Page 124 - Enter Temp

6 SPECIAL MODE (Menu Mode)6-1011 Press the [F4](CALC) key.*2) Z : Z coordinate dZ: Standard deviation[F4]12 Press the [F4](SET) key. *3)Z coordinat

Page 125

4 User1) This product is for professional use only!The user is required to be a qualified surveyor or have a good knowledge of surveying, in order to

Page 126

6 SPECIAL MODE (Menu Mode)6-116.1.4 Area CalculationThis mode calculate the area of a closed figure.There are two area calculation methods as follow

Page 127

6 SPECIAL MODE (Menu Mode)6-122) Area Calculation from Measured DataWhen 3 or more points are set, the area surrounded by the points is calculated

Page 128

6 SPECIAL MODE (Menu Mode)6-13● To change the display unitIt is possible to change the displayed area unit. When 3 or more points are measured, the

Page 129 - CURVATURE

6 SPECIAL MODE (Menu Mode)6-146.1.5 Point to Line MeasurementThis mode is used to obtain the coordinate data with the origin point A(0,0,0) and t

Page 130 - 14 POWER SOURCE AND CHARGING

6 SPECIAL MODE (Menu Mode)6-157Collimate prism P1 (Origin) and press [F1](MEAS) key.Measuring starts. *1)Input display of reflector B(P2) height wil

Page 131

6 SPECIAL MODE (Menu Mode)6-166.2 Setting the GRID FACTORGRID FACTOR can reset in this menu mode.For more information, refer to Section 8.1.1”Setti

Page 132 - 15 DETACH/ATTACH OF TRIBRACH

6 SPECIAL MODE (Menu Mode)6-176.3 Setting Illumination of Display and Cross Hairs Setting ON/OFF/LEVEL (1 to 9) for illumination of display (LCD)

Page 133 - DISTANCE MEAS

6 SPECIAL MODE (Menu Mode)6-186.4 Setting Mode 1In this mode, the following settings are possible.1. Setting Minimum Reading 2. Auto Power off

Page 134 - LANGUAGE * ENGLISH/

6 SPECIAL MODE (Menu Mode)6-196.4.2 Auto Power OffIf no key operation is given or no process of measurement is performed for more than 30 minutes (

Page 135

6 SPECIAL MODE (Menu Mode)6-206.4.3 Vertical and Horizontal Angle Tilt correction ( Tilt ON/OFF)(GPT-2009 has vertical angle tilt correction only.)

Page 136

5 Safety Standard for Laser Beam GPT-2000 series uses the invisible laser beam. The GPT-2000 series are manufactured and sold in accordance with &quo

Page 137 - 17 CHECK AND ADJUSTMENT

6 SPECIAL MODE (Menu Mode)6-216.4.5 Selecting Battery TypeOn-board battery BT-32Q can be also available for GPT-2000 series. When you use BT-32Q (N

Page 138

7 DATA COLLECTION7-17DATA COLLECTIONThe GPT-2000 is able to store the measured data into the internal memory.The internal memory is shared by the m

Page 139

7-2 7 DATA COLLECTION● Data collect menu operationBy pressing the [MENU] key, the instrument will be in MENU 1/3 mode.Press the [F1](DATA COLLECT) k

Page 140

7 DATA COLLECTION7-37.1 Preparation7.1.1 Selecting a File for Data CollectionA file used by data collection mode must be selected at first.Select a fi

Page 141

7-4 7 DATA COLLECTION7.1.2 Selecting a Coordinate File for Data CollectionWhen coordinate data in a coordinate data file are used for occupied point

Page 142

7 DATA COLLECTION7-54 Press the [F3](YES) key. [F3]5 Enter ID, INS.HT in the same way. *2),3)6 Press [F3](REC) key.Enter ID,INS.HT[F3]7 Press [F3](

Page 143

7-6 7 DATA COLLECTION● Example for setting the direction angle:The following is to memorize the data of the backsight after setting the backsight po

Page 144

7 DATA COLLECTION7-77.2 Operational Procedure of “DATA COLLECT”Operating procedure Operation Display1 Press the [F3](FS/SS) key from the data colle

Page 145 - Measuring point

7-8 7 DATA COLLECTION7.2.1 Searching the recorded dataWhile executing the DATA COLLECT mode, you can search the recorded data.7.2.2 Entering PCODE /

Page 146

7 DATA COLLECTION7-97.2.3 Entering PCODE / ID from the list of PCODEYou can also enter PCODE / ID from the list of PCODE.Operating procedure Operat

Page 147 - POWER ON

6 Contents FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 General Handling Precaut

Page 148

7-10 7 DATA COLLECTION7.3 Data Collect Offset Measurement modeThis mode is useful when it is difficult to set up the prism directly, for example at t

Page 149 - , and 3)

7 DATA COLLECTION7-115 Press the [F1](MEAS) key.Continuous measuring starts.[F1]6 Collimate point A0 using the horizontal motion clamp and horizon

Page 150 - 18 PRECAUTIONS

7-12 7 DATA COLLECTION7.3.2 Distance Offset Measurement The measurement of a place apart from a prism is possible by inputting offset horizontal dis

Page 151 - 19 SPECIAL ACCESSORIES

7 DATA COLLECTION7-135 Press the [F1](INPUT) key and enter Forward direction offset value. *1)[F1]Enter HD[F4]6 Collimate the prism.Collimate P7 Pr

Page 152

7-14 7 DATA COLLECTION7.3.3 Plane Offset MeasurementMeasuring will be taken for the place where direct measuring can not be done, for example distan

Page 153 - 19 SPECIAL ACCESSORIES

7 DATA COLLECTION7-155 Measure the second and third points in the same way. *1)Collimate P2[F1]Collimate P3[F1]The display changes to PT# input in

Page 154 - 20 BATTERY SYSTEM

7-16 7 DATA COLLECTION7.3.4 Column Offset MeasurementIf it is possible to measure circumscription point (P1) of column directly, the distance to the

Page 155 - Tilting triple

7 DATA COLLECTION7-177.4 NEZ Auto CalculationAs measured data is collected, coordinates are calculated and stored for traverse or topo collection.

Page 156 - Error code

7-18 7 DATA COLLECTION7.5 Editing PCODE Library [PCODE INPUT]PCODE data can be entered into PCODE Library in this mode.A PCODE is liked with a numbe

Page 157

7 DATA COLLECTION7-197.6 Setting Parameter of Data Collect [CONFIG.]In this mode, the following settings of data collect mode are possible.● Setti

Page 158 - 23 SPECIFICATIONS

7 6.1 Application Measurement (PROGRAMS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-26.1.1 Remote Elevation measurement

Page 159

8 LAYOUT8-18LAYOUT LAYOUT mode has two functions which are setting of layout points and setting new points using coordinate data in the internal me

Page 160

8 LAYOUT8-2● Layout menu operationBy pressing the [MENU] key, the instrument will be in MENU 1/3 mode.Press the [F2](LAYOUT) key, the menu of layo

Page 161 - APPENDIX

8 LAYOUT8-38.1 Preparation8.1.1 Setting the GRID FACTOR● Calculation Formula1) Elevation Factor2) Scale FactorScale Factor : Scale Factor at the su

Page 162 - APPENDIX-2

8 LAYOUT8-48.1.2 Selecting Coordinate Data File You can execute a Layout from selected coordinate data file, also you can record New point measured

Page 163 - APPENDIX-3

8 LAYOUT8-58.1.3 Setting Occupied Point Occupied point can be set by two setting methods as follow.1) Setting from the coordinate data stored in th

Page 164 - APPENDIX-4

8 LAYOUT8-6● Example setting :Setting Instrument point coordinates directlyOperating procedure Operation Display1 Press the [F1](OCC.PT INPUT) key

Page 165 - APPENDIX-5

8 LAYOUT8-78.1.4 Setting Backsight PointThe following three setting methods for Backsight point can be selected.1) Setting from the coordinate data

Page 166

8 LAYOUT8-8● Example setting: Setting the backsight point coordinates directly Operating procedure Operation Display1 Press the [F2](BACKSIGHT) key

Page 167

8 LAYOUT8-98.2 Executing a LayoutThe following methods can be selected for executing a Layout:1) Recalling points from internal memory by point num

Page 168 - GPT-2000 series

8 LAYOUT8-10● Point Guide Function (Only for Point Guide type)The point guide function can be used while executing a Layout.7 When the display val

Commentaires sur ces manuels

Pas de commentaire